DSpace Repository

Analysis of Principal Structural Orientation of Trabecular Bone Using Quantitative Ultrasound

Show simple item record

dc.contributor.advisor Qin, Yi-Xian en_US
dc.contributor.advisor Lin, Wei en_US
dc.contributor.author Lin, Liangjun en_US
dc.contributor.other Department of Biomedical Engineering en_US
dc.date.accessioned 2017-09-20T16:51:37Z
dc.date.available 2017-09-20T16:51:37Z
dc.date.issued 2014-12-01 en_US
dc.identifier.uri http://hdl.handle.net/11401/76994 en_US
dc.description 129 pgs en_US
dc.description.abstract Quantitative ultrasound (QUS) has been accepted widely as a non-invasive, economic, non-radioactive and portable modality for assessing bone heath status. This technology utilizes the basic physical mechanism of interaction between ultrasound wave and bone structure to provide mechanical and structural information of bone. Instead of only evaluating the quantity of bone like other traditional techniques such as duel energy X-ray absorptiometry (DXA), QUS is also capable of measuring the quality of bone such as anisotropy, microarchitecture and microfracture. This advantage of QUS is beneficial for treating the patient suffering from osteoporosis or other bone health deterioration, long term bed-rest patient and astronaut experiences low gravity environment. To improve the current QUS technology for bone mechanical properties assessment and fracture risk prediction, the focuses of this study are: 1) to develop a novel QUS measurement protocol to predict the principal structural orientation (PSO) of spherical trabecular bone model; 2) to use finite element analysis (FEA) to evaluate the mechanical properties in the PSO predicted by QUS; 3) to apply this novel QUS measurement on human calcaneus as an improved evaluation for the mechanical properties. It is shown that the PSO predicted by QUS is highly close to the PSO predicted by micro computed tomography (µCT), and the average angle difference is less than 5° using prediction of ultrasound velocity. The FEA simulation based on the µCT images showed the mechanical strength in the PSO predicted by QUS is significantly higher than the anatomical orientations and highly close to the value in longest vector of MIL tensor measured by µCT. By applying the same QUS measurement of PSO on bovine cubic bone samples and human calcaneus, the correlations between the QUS parameters and the mechanical and structural properties of trabecular bone were significantly improved (p<0.05), suggesting that such QUS measurement can be applied to human calcaneus evaluation and improves the reliability and accuracy for bone strength measurement and fracture risk assessment. en_US
dc.description.sponsorship This work is sponsored by the Stony Brook University Graduate School in compliance with the requirements for completion of degree. en_US
dc.format Monograph en_US
dc.format.medium Electronic Resource en_US
dc.language.iso en_US en_US
dc.publisher The Graduate School, Stony Brook University: Stony Brook, NY. en_US
dc.subject.lcsh Biomedical engineering en_US
dc.subject.other biomechanics, medical ultrasound imaging, osteoporosis, trabecular bone en_US
dc.title Analysis of Principal Structural Orientation of Trabecular Bone Using Quantitative Ultrasound en_US
dc.type Dissertation en_US
dc.mimetype Application/PDF en_US
dc.contributor.committeemember Dilmanian, F. Avraham en_US
dc.contributor.committeemember Li, Baosheng en_US
dc.contributor.committeemember Kaufman, Jonathan en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account